SCFHS Laboratory Specialist – Clinical Biochemistry Exam: free practice test

Start with 10 free questions to see what needs more practice. Finish to see your score, weakest units and every option explained.

Back to SCFHS Laboratory Specialist – Clinical Biochemistry Exam

Practice test questions with answers and explanations

Try the questions in the test above first, then open each one here to see the correct answer and why every other option is wrong.

01Serum from a patient with Waldenström macroglobulinaemia has a serum water fraction of 0.78 instead of the usual 0.93. Flame photometry on a diluted aliquot reports sodium 117 mmol/L. What sodium result is expected from a direct ISE on the undiluted serum?

Practice question Unit: Clinical Chemistry

  1. A109 mmol/L

    This multiplies the flame result by 0.93; the flame value first has to be divided by the actual water fraction of 0.78 to give the sodium in serum water.

  2. B117 mmol/L

    A direct ISE measures sodium in the water of undiluted serum and is not affected by electrolyte exclusion, so it does not reproduce the low flame result.

  3. C126 mmol/L

    This divides the flame result by the usual 0.93 instead of the patient's actual water fraction of 0.78, so the correction is too small.

  4. D140 mmol/L ✓ Correct answer

    Sodium in serum water is 117 ÷ 0.78 = 150 mmol/L; a direct ISE reports 0.93 × the water concentration whatever the water fraction, about 140 mmol/L.

Reference: Pseudohyponatremia: Mechanism, Diagnosis, Clinical Associations and Management 2023, section "3.1. Sodium Concentration Lowering by the Electrolyte Exclusion Effect"

02A 49-year-old woman attends a haematology clinic for routine review and feels well; her ECG is normal. Serum potassium is 6.4 mmol/L on a specimen with a normal haemolysis index that was centrifuged promptly. Her full blood count shows platelets 950 × 10^9/L, white cells 8 × 10^9/L and a normal haemoglobin. Which step best establishes her true potassium?

Practice question Unit: Clinical Chemistry

  1. ARepeat serum potassium on a fresh sample drawn with the hand relaxed

    Fist clenching can add 1–2 mmol/L, but a fresh serum sample still clots, and with marked thrombocytosis platelets again release potassium into the serum.

  2. BMeasure potassium in heparinised whole blood from a new venipuncture ✓ Correct answer

    With platelets at 950 × 10^9/L, potassium released from platelets in the clotted, centrifuged serum is the likely cause; in whole blood the platelets stay intact and the result reflects the true value.

  3. CStart potassium-lowering treatment and recheck serum potassium afterwards

    Treating a spurious serum value risks lowering a normal potassium; the true level should first be measured in a sample in which the platelets remain intact.

  4. DRe-centrifuge the same serum tube and repeat the potassium measurement

    Re-centrifuging the same serum cannot remove potassium that platelets have already released into it.

Reference: Preanalytical Variables and Their Influence on the Quality of Laboratory Results 2001 (EJIFCC), sections "Case #1" and "Case #2"

03A hypertriglyceridaemic sample gives a sodium of 141 mmol/L by direct ISE, which reports serum-water sodium multiplied by a fixed factor of 0.93, and 114 mmol/L by flame emission spectrophotometry, which measures sodium in whole serum. What is the approximate serum water fraction of this sample?

Practice question Unit: Clinical Chemistry

  1. A0.75 ✓ Correct answer

    Serum-water sodium is 141 / 0.93, about 151.6 mmol/L; whole-serum sodium equals that times the water fraction, so 114 / 151.6 gives about 0.75.

  2. B0.81

    This divides 114 by 141 directly, forgetting that the direct ISE result has already been scaled by 0.93.

  3. C0.87

    This divides the ratio 114/141 by 0.93 instead of multiplying, which reverses the conversion.

  4. D0.93

    0.93 is the normal serum water fraction assumed by the instruments; this sample's lipid content lowers it, which is why whole-serum sodium is low.

Reference: Pseudohyponatremia: Mechanism, Diagnosis, Clinical Associations and Management, Journal of Clinical Medicine 2023, section "3.1. Sodium Concentration Lowering by the Electrolyte Exclusion Effect"

04A patient with type 1 diabetes and a history of vomiting has an arterial blood gas of pH 7.32, pCO2 28 mmHg and HCO3 14 mmol/L. Electrolytes: Na 138, Cl 104 mmol/L (K omitted). Using expected pCO2 = 1.5 × HCO3 + 8 (± 2) and a normal anion gap of 8 ± 4 mmol/L, what is the best interpretation?

Practice question Unit: Clinical Chemistry

  1. AHigh-anion-gap metabolic acidosis with a superimposed respiratory alkalosis

    A superimposed respiratory alkalosis would push pCO2 below the expected 27 to 31 mmHg; 28 mmHg lies inside that range.

  2. BHigh-anion-gap metabolic acidosis with appropriate respiratory compensation ✓ Correct answer

    The pH is acidemic and HCO3 is low, so the process is metabolic; the gap is 138 − 104 − 14 = 20, and the expected pCO2 of 29 ± 2 matches the measured 28.

  3. CNormal-anion-gap metabolic acidosis with appropriate respiratory compensation

    A gap of 20 is far above 8 ± 4, so unmeasured anions are present and the acidosis is not of the normal-gap type.

  4. DHigh-anion-gap metabolic acidosis with a superimposed respiratory acidosis

    A superimposed respiratory acidosis would leave pCO2 above the expected 27 to 31 mmHg; the measured 28 mmHg lies inside that range.

Reference: Interpretation of arterial blood gas, Indian Journal of Critical Care Medicine 2010, section "Metabolic disorders"

05A 58-year-old woman with nephrotic syndrome has total calcium 2.38 mmol/L (laboratory reference interval 2.18–2.60 mmol/L), albumin 24 g/L and a raised intact PTH. Which interpretation is most appropriate?

Practice question Unit: Clinical Chemistry

  1. AThe total calcium is within the interval, so the raised PTH is most likely due to vitamin D deficiency and needs no calcium work-up

    Total calcium looks normal only because low albumin lowers it; the adjusted value is high, so attributing the PTH to vitamin D deficiency without adjusting misses the diagnosis.

  2. BThe adjusted calcium is about 2.7 mmol/L, so she is hypercalcaemic and the PTH points to primary hyperparathyroidism ✓ Correct answer

    Total calcium should be adjusted for albumin; with albumin 24 g/L the adjusted value is about 2.7 mmol/L, above the interval, and hypercalcaemia with a raised PTH makes primary hyperparathyroidism the most likely diagnosis.

  3. CThe low albumin implies her ionised calcium is low, so the raised PTH is an appropriate response to true hypocalcaemia

    Low albumin is a reason to adjust total calcium, not to infer a low ionised calcium; once adjusted, the calcium is high, which does not fit a compensatory PTH rise.

  4. DThe calcium result is unreliable in nephrotic syndrome, so PTH should be repeated before the calcium is interpreted

    The albumin adjustment is exactly what makes the result interpretable; calling the result unreliable avoids applying the correction.

Reference: Primary hyperparathyroidism: review and recommendations on evaluation, diagnosis, and management. A Canadian and international consensus, Osteoporosis International 2016, section "How is primary hyperparathyroidism diagnosed today?"

06A patient with polyuria produces 4.32 L of urine in 24 hours with a urine osmolality of 400 mOsm/kg. Assuming 1 kg of urine is about 1 L, which osmole excretion rate and interpretation are correct?

Practice question Unit: Urinalysis and Other Body Fluids

  1. A0.12 mOsm/min: low rate, suggesting a medullary concentrating defect

    This value comes from a decimal slip; 4.32 L per day is 3.0 mL/min, and 3.0 × 400 gives 1.2 mOsm/min.

  2. B0.50 mOsm/min: usual rate, suggesting primary polydipsia

    About 0.5 mOsm/min is the usual rate on a typical diet, not the calculated result, and a urine osmolality above 300 argues against a water diuresis such as primary polydipsia.

  3. C1.20 mOsm/min: raised rate, suggesting an osmotic diuresis ✓ Correct answer

    4.32 L per 1,440 min is 3.0 mL/min, and multiplying by 400 mOsm/L gives 1.2 mOsm/min; a rate above 1 mOsm/min is usual in an osmotic diuresis.

  4. D12.0 mOsm/min: raised rate, suggesting an osmotic diuresis

    The interpretation would follow from a high rate, but the figure is ten times too large; the correct rate is 1.2 mOsm/min.

Reference: Use of Urine Electrolytes and Urine Osmolality in the Clinical Diagnosis of Fluid, Electrolytes, and Acid-Base Disorders (Kidney International Reports 2021), section "Polyuria Due to an Osmotic Diuresis"

07A 3-year-old with recurrent pyogenic infections has a markedly raised serum IgM, with very low IgG, IgA and IgE. CD19 B-cell counts are normal. Which pair of flow cytometry assays best targets the most likely cause?

Practice question Unit: Immunology and Serology

  1. ACD40 on B cells, and inducible CD40 ligand (CD154) on activated CD4 T cells ✓ Correct answer

    This pattern suggests hyper-IgM syndrome, for which CD40 on B cells and inducible CD154 on activated CD4 T cells are evaluated after in vitro stimulation.

  2. BHLA-DR on B cells and monocytes, and CD18/CD11a on neutrophils

    HLA-DR and CD18/CD11a are used when MHC class II deficiency or leukocyte adhesion deficiency is suspected, not for a hyper-IgM pattern.

  3. CCD3, CD4 and CD8 counts on T cells, and CD16/CD56 on natural killer cells

    Lymphocyte subset counts do not examine the CD40 receptor and ligand pair, and B-cell numbers are already known to be normal here.

  4. DCD45RA and CD45RO on T cells, and CD31 on CD4 T cells to identify recent thymic emigrants

    These markers describe naive, memory and recent thymic emigrant T cells and do not test the CD40 pathway.

Reference: Diagnostic utility of targeted flow cytometry in genetically confirmed inborn errors of immunity: a 20-year single-center experience, Frontiers in Immunology 2026, section "Cell surface protein expression"

08A 66-year-old has an IgA M-protein of 18 g/L on SPEP. The serum free light chain ratio is normal, bone marrow plasma cells are 6%, and there is no anemia, renal impairment, hypercalcemia or bone disease. Applying the Mayo risk model for MGUS progression, how should this patient be classified?

Practice question Unit: Immunology and Serology

  1. AMGUS with no risk factors, because the serum free light chain ratio is normal and plasma cells are low

    A normal free light chain ratio removes only one of the three Mayo factors; the M-protein level and the IgA isotype still count.

  2. BMGUS with one risk factor, because the IgA isotype is not counted in the Mayo model

    The Mayo model counts non-IgG isotype (IgA or IgM) as a risk factor, so the IgA isotype is counted alongside the M-protein level.

  3. CMGUS with two risk factors: M-protein level of 15 g/L or more and IgA isotype ✓ Correct answer

    This is MGUS (M-protein under 30 g/L, under 10% plasma cells, no end-organ damage); an M-protein of 15 g/L or more and a non-IgG (IgA) isotype are two of the three Mayo factors.

  4. DMGUS with three risk factors, counting the 6% marrow plasma cells as the third

    The three Mayo factors are M-protein of 15 g/L or more, non-IgG isotype and an abnormal free light chain ratio; marrow plasma cell percentage is not one of them.

Reference: Diagnosis and management of monoclonal gammopathies, CMAJ 2026, section "What is the risk of progression from MGUS to plasma cell disorders or lymphoproliferative neoplasms?"

09A laboratory evaluates a creatinine assay. The control material's peer-group mean is 100 µmol/L, the laboratory's own mean over the month is 105 µmol/L, and the CV is 3%. The allowable total error (TEa) for the test is 15%. What is the sigma metric of the assay?

Practice question Unit: Laboratory Operations

  1. A1.7

    Uses the bias in place of the allowable error budget, so it understates performance; the metric must compare the error left after bias with imprecision.

  2. B3.3 ✓ Correct answer

    The lab mean sits 5% above the peer mean, which leaves 10% of the 15% TEa; dividing by the 3% CV gives about 3.3.

  3. C5.0

    Divides TEa by CV and ignores bias, which overstates performance because bias consumes part of the allowable error.

  4. D6.7

    Adds the bias to TEa, but bias always shrinks the allowable error rather than enlarging it.

Reference: Analytical Sigma metrics: A review of Six Sigma implementation tools for medical laboratories, Biochemia Medica 2018, section "The unique challenge of laboratory testing for Six Sigma – why we calculate rather than count a Sigma metrics for analytical methods"; Internal Quality Controls in the Medical Laboratory: A Narrative Review of the Basic Principles of an Appropriate Quality Control Plan, 2024, section "Mean and Bias"

10On two medical wards, rejections for infusion-contaminated (diluted) samples rose from about 5 to 35 a month, while all other wards stayed level. Ward nurses draw most samples on these two wards, and a group of newly qualified nurses started there in the month the rise began. A new hospital-wide courier schedule began in the same month. Which response best fits a root cause analysis approach?

Practice question Unit: Patient Safety and Professionalism

  1. AShorten transport time from the two wards, since delays before analysis dilute samples

    Dilution comes from infusion fluid entering the sample at collection, not from time in transit, and the courier change was hospital-wide while only these two wards rose.

  2. BIssue written warnings to the nurses whose samples were rejected most often this month

    Warning individuals is a person approach; root cause analysis looks for the underlying cause, here the sampling technique of staff new to the wards.

  3. CTrain the newly joined nurses to sample away from infusion sites and track monthly rates ✓ Correct answer

    The rise is confined to the wards where new nurses started, pointing to sampling technique; training in drawing from the arm opposite an infusion, then tracking the monthly rate, addresses the cause and checks the fix.

  4. DAdd a reception rule that flags likely infusion-diluted samples so more of them are caught

    Better detection catches more diluted samples after they are drawn but leaves the collection technique that produces them unchanged.

Reference: Challenges in Preanalytical Phase of Laboratory Medicine: Rate of Blood Sample Nonconformity in a Tertiary Care Hospital, EJIFCC 2020, section "Discussion"

Lab Clinical Biochemistry Specialist

Full prep for this exam

All of this in one purchase.

  • Full mock exam, same as the real one150 questions in 180 minutes. You get a total score and a score for every unit.
  • Practice unit by unit595 questions, every option explained with its source. Starts with your weakest units.
  • Complete Review Guide 2026–2027 (PDF)Ordered by each unit's weight in the exam. With lifetime access only.

Choose your access

One step before payment

Continue with your Google account and you go straight to the payment page.

Check my score freeFull prep