Try the questions in the test above first, then open each one here to see the correct answer and why every other option is wrong.
01A febrile adult has two blood culture sets from separate peripheral venipunctures. One aerobic bottle from a single set turns positive with coagulase-negative staphylococci. All other bottles are negative at 5 days. What is the most likely interpretation?
Practice question Unit: Microbiology
AProbable true bacteraemia needing full susceptibility testing
A single positive bottle of a common skin organism, with other sets sterile, does not support true infection, so full workup is rarely warranted.
BInstrument malfunction producing a false-positive signal
A true false-positive signal would show no organisms on subculture, but here organisms were recovered and identified, which points to contamination at collection.
CProbable skin-flora contaminant needing abbreviated work-up ✓ Correct answer
Coagulase-negative staphylococci in one set only fit a skin-flora contaminant; the laboratory may identify briefly and add a comment inviting a call.
DReagent contamination affecting every bottle in the batch
Reagent contamination would affect many bottles in the batch, whereas here the other bottles stayed sterile for five days.
Reference: Guide to Utilization of the Microbiology Laboratory for Diagnosis of Infectious Diseases: 2013 Recommendations (IDSA/ASM), Clin Infect Dis 2013, Section I "Bloodstream Infections and Infections of the Cardiovascular System", paragraph on common blood culture contaminants
Ask a friend
02A stool specimen from a patient with watery diarrhoea is plated on blood agar and TCBS agar. The TCBS plate stays sterile at 24 hours, yet an oxidase-positive Gram-negative rod grows on blood agar, and Aeromonas is suspected. Which extra medium best supports isolation?
Practice question Unit: Microbiology
AThayer–Martin agar incubated in 5–10% CO2 for 48 hours
Thayer–Martin agar is a selective medium for pathogenic Neisseria, and its CO2 atmosphere and agents do not suit isolation of Aeromonas from stool.
BMannitol salt agar incubated in air for 24–48 hours with daily reading
Mannitol salt agar is selective for staphylococci through its high salt content, which would block Gram-negative rods such as Aeromonas.
CCefsulodin–irgasan–novobiocin agar incubated in air for 24–48 hours ✓ Correct answer
TCBS inhibits Aeromonas, so a plate without growth does not exclude it, and cefsulodin–irgasan–novobiocin agar is the selective stool medium for aeromonads.
DCharcoal yeast extract agar incubated in moist air for 10 days
Charcoal yeast extract agar with cysteine is for Legionella, and a ten-day incubation would not help recover a fast-growing enteric organism.
Reference: UK SMI ID 19, Identification of Vibrio and Aeromonas species, Issue 3.1 (UKHSA), section 8.2 "Primary isolation media"
Ask a friend
03Gram-positive cocci in clusters grow from a positive blood culture of a patient with suspected endocarditis. The latex agglutination test shows clumping, the tube coagulase test is negative and the PYR test is positive. Which organism best explains this combination?
Practice question Unit: Microbiology
AStaphylococcus lugdunensis ✓ Correct answer
S. lugdunensis can express clumping factor, giving positive latex or slide results despite negative tube coagulase, and it is typically PYR positive.
BStaphylococcus aureus
S. aureus is tube coagulase positive and PYR negative, which does not match these results.
CStaphylococcus epidermidis
S. epidermidis is negative in latex, tube coagulase and PYR tests, so it would not clump.
DStaphylococcus saprophyticus
S. saprophyticus is negative in coagulase and PYR tests and is mainly a urinary pathogen.
Reference: UK Standards for Microbiology Investigations ID 7, "Identification of Staphylococcus species, Micrococcus species and Rothia species", Issue 5 (UKHSA, 2026), section 6.4.2 "Biochemical tests" and Table 2
Ask a friend
04A large Gram-positive rod forms flat, grey-white, tacky colonies with irregular edges on horse blood agar after 24 hours. It is non-haemolytic, non-motile on motility testing and inhibited by penicillin. Which organism fits best?
Practice question Unit: Microbiology
ABacillus cereus
This species is usually motile, clearly haemolytic on blood agar and resistant to penicillin, so it does not match.
BBacillus anthracis ✓ Correct answer
The combination of no haemolysis, no motility and penicillin susceptibility separates this species from the rest of its group.
CBacillus thuringiensis
Motile, haemolytic and penicillin resistant, with parasporal crystals in sporulating culture, which rules out the isolate described.
DBacillus mycoides
It is non-motile like the isolate, but it is haemolytic, forms rhizoid spreading colonies and is penicillin resistant.
Reference: UK Standards for Microbiology Investigations ID 9, "Identification of Bacillus species", Issue 3.2 (UKHSA, 2025), section "Identification" (test results and colonial appearance tables)
Ask a friend
05A laboratory screens stools with sorbitol MacConkey culture only and reports no E. coli O157. A later PCR panel detects the Shiga toxin gene in a child with haemolytic uraemic syndrome, although the culture grew only pink colonies. Which explanation best fits?
Practice question Unit: Microbiology
AA non-O157 STEC was present, and it ferments sorbitol like commensal E. coli ✓ Correct answer
Sorbitol-based culture only picks out O157, and non-O157 STEC ferment sorbitol, so they look like harmless E. coli until a stx assay is used.
BThe O157 strain lost its Shiga toxin gene during overnight growth on the plate
Gene loss during one overnight incubation is not the usual reason for a missed STEC; the limit lies in what the plate detects.
CThe PCR amplified commensal E. coli, because stx genes are present in nearly all strains of the species
Shiga toxin genes mark a defined group of pathogenic strains, so commensal E. coli would not generate a positive result on a stx target.
DThe toxin gene was carried by a Salmonella isolate that was overgrown by pink colonies
Shiga toxin production defines STEC, which is a group of E. coli; Salmonella does not carry this gene, so it cannot explain the positive PCR.
Reference: UK Standards for Microbiology Investigations, ID 22 "Identification of Shiga toxin-producing Escherichia coli (STEC)", Issue 5.1 (UKHSA, 2025), sections "Identification" and "Technical information and limitations"
Ask a friend
06A catheter-associated infection in an immunocompromised patient yields Gram-negative rods forming rough, wrinkled colonies that adhere to the agar and produce a non-diffusible yellow pigment. The isolate is oxidase negative and grows at 42°C. Which organism is most likely?
Practice question Unit: Microbiology
APseudomonas aeruginosa
This species is oxidase positive and forms large smooth flat colonies, not yellow wrinkled adherent ones, so the oxidase result rules it out.
BPseudomonas oryzihabitans ✓ Correct answer
Yellow non-diffusible pigment, wrinkled adherent colonies, negative oxidase and growth at 42°C together identify this species, which causes infection mainly in immunocompromised hosts.
CPseudomonas stutzeri
Colonies are wrinkled and adherent here too, but they are dark brown and the species is oxidase positive, so it does not fit.
DBurkholderia cepacia complex
Members of this complex are oxidase positive and give smooth colonies on blood agar, so a negative oxidase result excludes them.
Reference: UK Standards for Microbiology Investigations, ID 17 "Identification of Pseudomonas species and other non-glucose fermenters", Issue 4.1 (UKHSA, 2025), section 8.2 (Table 1) and section 8.4.1 (Table 2)
Ask a friend
07A symptomatic woman's urine was collected into a boric acid container that was filled with only a small fraction of its marked volume. It reached the laboratory after 48 hours at room temperature. Unspun urine shows many white cells, but culture shows no growth. Which explanation is most likely?
Practice question Unit: Urinalysis and Other Body Fluids
ABacteria multiplied during transport and were then overgrown by a second organism that hid them
Boric acid holds the bacterial population steady rather than allowing overgrowth, so multiplication during transport does not explain the lack of growth.
BStorage for 48 hours at room temperature killed the common urinary pathogens before culture
A correctly filled boric acid container keeps organisms viable for 48 hours or more, so the delay alone does not account for the sterile culture.
CThe white cells were squamous cells from contamination, so a sterile culture is expected
White cells indicate inflammation, whereas squamous cells point to contamination, which would more often give mixed growth rather than none.
DUnderfilling left the preservative too concentrated, which inhibited bacterial growth ✓ Correct answer
Too little urine in the container leaves the boric acid at an inhibitory concentration, so organisms that were genuinely present can fail to grow despite pyuria.
Reference: UK Standards for Microbiology Investigations B 41 "Investigation of urine", Issue 8.8, UKHSA, section 5 "Technical information/limitations" (Transport of urine specimens), section 7.3 "Adequate quantity and appropriate number of specimens" and section 8.1
Ask a friend
08A smoker with no allergy symptoms has a raised total IgE. Stool examination shows helminth ova. Which interpretation is most appropriate?
Practice question Unit: Immunology and Serology
AThe IgE rise confirms an unrecognised food allergy that needs a specific IgE panel
Without symptoms, a food allergy is not supported; a specific IgE panel would risk misleading positive results.
BThe IgE rise indicates a complement deficiency that disturbs antibody production
Complement deficiency affects the complement cascade, not IgE levels, and would not be shown by a raised IgE.
CThe IgE rise is a laboratory artefact, so the sample should be rejected and redrawn
Raised IgE is a known biological effect of helminth infection, so the result is real and should not be discarded.
DThe IgE rise is explained by the parasites and does not by itself show allergy ✓ Correct answer
Parasitic infection, and smoking too, can raise IgE, so the result does not prove an allergy in this patient.
Reference: MedlinePlus (NLM), "Allergy Blood Test", section "Is there anything else I need to know about an allergy blood test?"
Ask a friend
09During one run, a two-level QC scheme gives control 1 at +2.3 SD and control 2 at +2.4 SD from their respective means. Neither value exceeds 3 SD. Which interpretation and action fit best?
Practice question Unit: Laboratory Operations
AAn R-4s violation indicating random error; repeat the run without any further investigation or checks
R-4s needs one control above +2 SD and another below -2 SD in the same run; here both deviate in the same direction.
BA 1-2s warning only; report patient results and review the chart at the end of the week
A 1-2s warning concerns a single control beyond 2 SD; two controls exceeding the same limit is a stronger, reject-level signal.
CA 4-1s violation indicating gradual drift; report results now and recalibrate at the next maintenance
A 4-1s violation needs four consecutive values beyond 1 SD on one side; only two values are available here.
DA 2-2s violation indicating systematic error; stop and troubleshoot before reporting results ✓ Correct answer
Two consecutive control values beyond the same 2 SD limit on the same side break the 2-2s rule, which detects systematic error and calls for troubleshooting.
Reference: UK Standards for Microbiology Investigations, Q 2 "Quality assurance in the diagnostic infection sciences laboratory", Issue 8.1 (UKHSA, 2025), section 6.4.2 "Westgard rules", Table 1
Ask a friend
10A culture report for patient X was released and later found to belong to patient Y because two tubes were swapped at collection. Which action is remedial rather than corrective or preventive?
Practice question Unit: Patient Safety and Professionalism
ARetraining collectors in bedside labeling after reviewing the investigation findings
Retraining addresses why the error happened so that it does not recur, which makes it a corrective action rather than a remedy for this report.
BIntroducing barcode scanning of wristbands and tubes at the point of collection
A new scanning system also targets the cause of the swap, so it is a corrective measure to stop repetition.
CReviewing other collection steps for weak points before similar errors appear
Looking for weak points before errors occur is preventive action, a planned evaluation of processes aimed at errors not yet made.
DNotifying the clinician at once and issuing the correct result to each patient ✓ Correct answer
Remediation fixes the consequences of an error already made, and telling those concerned and supplying the right result is the immediate step.
Reference: WHO Laboratory Quality Management System: A Handbook, version 1.1 (2011), Chapter 14 "Occurrence management", section 14-4 "Rectifying and managing occurrences"
Ask a friend