01A technician has a stone cast of a premolar with a large pointed buccal cusp, a very small nonfunctional lingual cusp, a prominent transverse ridge and a mesiolingual developmental groove. Which tooth is it?

Practice question Unit: Dental Anatomy and Occlusion

  1. AMandibular first premolar ✓ Correct answer

    A dominant buccal cusp, tiny nonfunctional lingual cusp, transverse ridge and mesiolingual groove together identify the mandibular first premolar.

  2. BMandibular second premolar

    The mandibular second premolar has a well-developed lingual cusp or cusps and lacks the mesiolingual groove and strong transverse ridge.

  3. CMaxillary first premolar

    The maxillary first premolar has two well-developed cusps of similar height and a mesial depression, not a tiny lingual cusp.

  4. DMaxillary second premolar

    The maxillary second premolar has two nearly equal cusps and a smooth mesial surface, unlike a very small lingual cusp.

Reference: SCFHS Dental Lab Technician Content Guideline (V1.220901), Section 1 Dental Anatomy and Occlusion, p. 2; Woelfel and Scheid, Dental Anatomy: Its Relevance to Dentistry, latest edition

02Two cast alloys of similar cost are considered for a crown whose thin margin will be burnished against the die. Alloy P has a lower yield strength and greater percent elongation than alloy Q. Which choice and reason are correct?

Practice question Unit: Dental Materials

  1. AAlloy P, because it deforms plastically at low stress and stretches without cracking ✓ Correct answer

    Burnishing is plastic deformation; low yield strength lets the margin adapt with modest force, and high elongation prevents cracking as it is worked.

  2. BAlloy Q, because its higher yield strength lets the margin hold its shape when burnished

    High yield strength resists plastic flow, so the margin would resist adaptation and need excessive force, risking distortion of the casting.

  3. CAlloy Q, because its lower elongation means less springback at the margin

    Low elongation signals limited ductility, so burnishing could crack the margin; springback depends on the yield-to-modulus ratio, not elongation.

  4. DAlloy P, because a lower yield strength always means a lower modulus of elasticity

    Yield strength and modulus are independent; lower yield says nothing about stiffness, so this reason is unsound even though alloy P is the right choice.

Reference: SCFHS Dental Lab Technician Content Guideline (V1.220901), Section 2 Dental Materials, p. 2; Anusavice, Phillips' Science of Dental Materials, latest edition

03Two alginate impressions of the same arch are made. One is left in open air for an hour, the other is stored immersed in water for an hour, then both are poured. What is expected?

Practice question Unit: Removable Complete Prosthesis

  1. ABoth casts are accurate because the set gel is dimensionally stable

    Set alginate exchanges water with its surroundings, so it is not dimensionally stable in air or water.

  2. BThe air-stored cast is undersized and rough; the water-stored cast is enlarged ✓ Correct answer

    Syneresis in air shrinks and roughens the gel, while imbibition in water swells it, giving a larger cast.

  3. CThe air-stored cast is enlarged; the water-stored cast is undersized and rough

    This reverses the effects; air loses water and shrinks the gel, whereas immersion swells it.

  4. DBoth casts are undersized because the gel contracts as it ages

    Immersion would add water, not remove it; only the air-stored impression would contract.

Reference: SCFHS Dental Lab Technician Content Guideline (V1.220901), Section 3 Removable Complete Prosthesis, p. 2; Anusavice, Phillips' Science of Dental Materials, latest edition

04A die poured from a PVS impression of a premolar has no stone detail along a short stretch of the finish line, where the impression held a bubble. What is the best action?

Practice question Unit: Fixed Restorations

  1. AEstimate the missing line from the impression and carve it into the die

    Guessing the line places the margin where the technician imagines it, so the crown may be over- or underextended on the tooth.

  2. BFill the void in the die with wax and judge the margin by eye

    Wax cannot recreate the true margin, so a pattern judged by eye reproduces a line that may not exist on the tooth.

  3. CReturn the impression and ask the dentist to retake it ✓ Correct answer

    The finish line is not recorded there, so the margin cannot be reconstructed and a retake is the only safe choice.

  4. DSmooth over the void with die hardener and use the impression as poured

    Hardener only coats the surface and cannot restore finish-line detail that the impression never recorded in the first place.

Reference: SCFHS Dental Lab Technician Content Guideline (V1.220901), Section 4 Fixed Restorations, p. 2; Rosenstiel, Land and Fujimoto, Contemporary Fixed Prosthodontics, 5th edition

05A mandibular Class I arch has sound first premolars as principal abutments. The dentist wants to reduce torque on them when the tissue-supported bases move under load. Which retainer assembly is best?

Practice question Unit: Removable Partial Prosthesis

  1. ADistal rest with a circumferential clasp engaging a distobuccal undercut

    A distal rest causes the abutment to tip distally, and a distobuccal retentive arm increases torque when the base rotates.

  2. BMesial rest, proximal plate and I-bar at the buccal gingival third ✓ Correct answer

    The mesial rest moves the fulcrum forward, so the I-bar and proximal plate swing gingivally and disengage when the base is loaded.

  3. CMesial rest with a circumferential clasp engaging a mesiobuccal undercut

    The mesial rest helps, but a retentive circumferential arm still tightens on the tooth and does not release torque as an I-bar does.

  4. DDistal rest with a bar clasp and no distal proximal plate or guide plane

    A distal rest with no proximal plate has no way to release stress and puts the abutment at greatest torque risk.

Reference: SCFHS Dental Lab Technician Content Guideline (V1.220901), Section 5 Removable Partial Prosthesis, p. 2; McGivney, Carr and McCracken, McCracken's Removable Partial Prosthodontics, latest edition

06On a master cast verified as accurate, a cast screw-retained framework is seated and the screw at one terminal abutment is tightened, and a gap appears at the opposite terminal abutment. What does this indicate, and what is the usual next step?

Practice question Unit: Dental Implant Prosthesis

  1. AThe fit is acceptable because tightening the other screws closes the gap

    Pulling a misfitting framework down with screws creates stress on implants, so this gap cannot be accepted.

  2. BThe framework is not passive, so it is sectioned and rejoined ✓ Correct answer

    A gap with a verified cast shows framework distortion, so the framework is sectioned and rejoined with the segments seated.

  3. CThe cast is inaccurate, so a new impression is required

    The cast was verified accurate, so the cause lies in the framework, not the impression or cast.

  4. DThe analog is loose, so the cast must be repoured

    A loose analog would be found during cast verification, and repouring would not correct framework distortion.

Reference: SCFHS Dental Lab Technician Content Guideline (V1.220901), Section 6 Dental Implant Prosthesis, p. 2; Drago and Peterson, Implant Laboratory Procedures: A Step-by-Step Guide, latest edition

07A Hawley retainer fits the master cast perfectly, but the patient cannot seat it fully in the mouth when it is delivered three weeks after the impression. Which cause is most consistent?

Practice question Unit: Orthodontic Appliances

  1. APolymerization shrinkage of the baseplate acrylic during processing

    Shrinkage of the acrylic would also prevent seating on the master cast, which the retainer fits perfectly, so it is not the cause.

  2. BDistortion of the labial bow during trimming

    A distorted bow would also show when the retainer is tried on the master cast, so this cannot explain the finding.

  3. CExpansion of the stone cast while the appliance was processed

    Stone expansion would make the appliance slightly larger than the mouth, giving looseness, not a failure to seat, and the cast fit stays good.

  4. DShifting of the teeth in the arch during the laboratory period ✓ Correct answer

    Only a change in the mouth explains a fit on the cast but not on the teeth; teeth shift when no appliance holds them.

Reference: SCFHS Dental Lab Technician Content Guideline (V1.220901), Section 7 Orthodontic Appliances, p. 2; Johnson, Patrick, Stokes, Wildgoose and Wood, Basics of Dental Technology: A Step by Step Approach, 2nd edition

08A lead-lined shielding stent is made for a patient with metal restorations in the beam path. Why must the lead surface facing the tissues be covered with a layer of acrylic?

Practice question Unit: Maxillofacial Prosthesis

  1. ATo raise attenuation of the primary beam through the lead

    Attenuation depends on lead thickness; the acrylic covering adds almost nothing to blocking the primary beam.

  2. BTo protect the lead sheet from heat distortion during acrylic processing

    Acrylic processing temperatures do not distort lead sheet, so the tissue-side layer is placed for dose reasons, not heat protection.

  3. CTo stop the lead from corroding in saliva during the course of treatment

    Encasing lead does keep it out of saliva, but the required tissue-side thickness is set by absorbing scattered electrons.

  4. DTo absorb secondary electrons from the lead before they reach mucosa ✓ Correct answer

    Lead emits low-energy secondary electrons; a low-atomic-number acrylic layer absorbs them before they reach the mucosa.

Reference: SCFHS Dental Lab Technician Content Guideline (V1.220901), Section 8 Maxillofacial Prosthesis, p. 2; McKinstry, Fundamentals of Facial Prosthetics, latest edition

09A technician soaks an alginate impression in disinfectant for far longer than the label allows, then pours it. The cast surface is rough and dimensionally inaccurate. Which explanation fits best?

Practice question Unit: Infection Control

  1. AResidual disinfectant raised the stone's setting temperature and expanded it

    Disinfectant residue does not raise stone temperature enough to distort a cast, and heat would not roughen the surface.

  2. BProlonged immersion let the gel take up liquid and swell, softening its surface ✓ Correct answer

    Alginate is a hydrocolloid, so long immersion causes imbibition, swelling and surface breakdown, giving a rough and inaccurate cast.

  3. CThe alginate lost water by syneresis during the soak and shrank

    Syneresis is water loss from a gel left in air; immersed in liquid the gel takes up water instead.

  4. DThe stone was mixed with too little water, raising its setting expansion

    A low water-powder ratio changes stone strength and expansion but is unrelated to the soak and does not roughen the surface.

Reference: SCFHS Dental Lab Technician Content Guideline (V1.220901), Section 9 Infection Control, p. 2; Anusavice, Phillips' Science of Dental Materials, latest edition

10A sandblasting cabinet used for cast alloy frameworks is fully enclosed, yet fine dust escapes around the door seal and settles on the bench during use. The seal is intact and the air supply pressure is normal. Which cause is the most likely?

Practice question Unit: Health and Safety

  1. AA clogged extraction filter that has cut negative pressure inside the cabinet ✓ Correct answer

    Reduced extraction airflow lets cabinet pressure rise, so dust-laden air leaks out through small gaps instead of being drawn to the filter.

  2. BAbrasive particles that are too coarse for the alloy being cleaned in the cabinet

    Coarser abrasive tends to produce less airborne fine dust, so coarse particles would not explain dust leaking out at the seal.

  3. CGloves in the cabinet that are slightly too small for the operator

    Glove fit affects comfort and control but does not change the airflow balance that keeps dust inside an enclosed cabinet.

  4. DAbrasive that has been recycled many times and broken down into fines

    Worn abrasive raises the dust load, but working extraction keeps the cabinet under negative pressure, so dust is drawn inward rather than leaking out.

Reference: SCFHS Dental Lab Technician Content Guideline (V1.220901), Section 10 Health and Safety, p. 2; Johnson, Patrick, Stokes, Wildgoose and Wood, Basics of Dental Technology: A Step by Step Approach, 2nd edition

Dental Lab Technician

Full prep for this exam

All of this in one purchase.

  • Full mock exam, same as the real one150 questions in 180 minutes. You get a total score and a score for every unit.
  • Practice unit by unit591 questions, every option explained with its source. Starts with your weakest units.
  • Complete Review Guide 2026–2027 (PDF)Ordered by each unit's weight in the exam. With lifetime access only.

Choose your access

One step before payment

Continue with your Google account and you go straight to the payment page.

Check my score freeFull prep