Try the questions in the test above first, then open each one here to see the correct answer and why every other option is wrong.
01A procedure delivers equivalent doses of 10 mSv to the lung and 20 mSv to the thyroid, and negligible dose elsewhere. Using ICRP 103 tissue weighting factors (lung 0.12, thyroid 0.04), what is the effective dose?
Practice question Unit: Radiation Protection
A2.8 mSv
This swaps the weighting factors, using 0.04 for the lung and 0.12 for the thyroid, which gives 0.4 plus 2.4.
B15 mSv
This is the simple mean of the two equivalent doses. Effective dose needs each dose multiplied by its tissue weighting factor.
C30 mSv
This simply adds the two equivalent doses and ignores the tissue weighting factors, which are all below one.
D2.0 mSv ✓ Correct answer
E is the sum of wT × HT: 0.12 × 10 = 1.2 plus 0.04 × 20 = 0.8, which gives 2.0 mSv.
Reference: IAEA Diagnostic Radiology Physics (2014), Section 22.3.4 (Effective dose, Table 22.1)
Ask a friend
02A technician notes that the spectrum of a tungsten-anode tube at 60 kV contains no K characteristic lines. What is the reason?
Practice question Unit: X-ray
AThe 2.5 mm Al filtration absorbs the K radiation completely
Typical filtration of 2.5 mm Al absorbs the L radiation completely, but it does not remove tungsten K radiation at higher voltages.
BElectron energy is under tungsten's 69.5 keV K-shell binding energy ✓ Correct answer
A K-shell vacancy needs an electron with more kinetic energy than 69.5 keV, which a 60 kV tube cannot supply.
CThe high atomic number of tungsten suppresses all characteristic emission
Tungsten does produce K lines at high enough voltage; its high atomic number actually favours the bremsstrahlung yield.
DThe tube current is too low to create enough K-shell vacancies
Tube current scales the number of photons but does not decide whether the K shell can be ionized; that depends on electron energy.
Reference: IAEA Diagnostic Radiology Physics (2014), Section 5.2.2 (Characteristic radiation)
Ask a friend
03A scanner has 16 detector rows of 1.25 mm, so the nominal beam width is 20 mm. In a helical scan the table moves 30 mm during each 360° rotation. What is the pitch?
Practice question Unit: CT
A1.5 ✓ Correct answer
Pitch is table translation per 360° rotation divided by nominal beam width: 30 mm divided by 20 mm gives 1.5.
B0.67
0.67 inverts the ratio: it is 20 divided by 30 rather than table travel divided by beam width.
C1.0
A pitch of 1.0 would need the table to move exactly 20 mm per rotation, equal to the nominal beam width.
D2.0
2.0 would need 40 mm of table travel per rotation for this 20 mm beam; 30 mm gives a smaller ratio.
Reference: IAEA Diagnostic Radiology Physics (2014), Section 11.5.3 (Helical CT scan)
Ask a friend
04At 1.5 T the ratio of parallel to antiparallel proton spins is about 1.000010. Roughly how many excess parallel spins are there in a group of 2 million spins?
Practice question Unit: MRI
A1
An excess of one spin would need a ratio of only about 1.0000010, ten times closer to unity than the stated value.
B100
An excess of 100 spins would need a ratio near 1.0001, ten times larger than the stated value at 1.5 T.
C1000
An excess of 1000 spins would need a ratio near 1.001, far above the tiny polarization that actually exists at 1.5 T.
D10 ✓ Correct answer
Each half holds about one million spins, and a ratio of 1.00001 means about ten more spins point along the field.
Reference: IAEA Diagnostic Radiology Physics (2014), Section 14.2.2 (External magnetic field and magnetization)
Ask a friend
05An ultrasound pulse meets a boundary at normal incidence. Fat has an acoustic impedance of 1.38 MRayl and liver 1.65 MRayl. What is the magnitude of the pressure reflection coefficient?
Practice question Unit: Ultrasound
A0.008
0.008 is the intensity reflected (R squared), not the pressure reflection coefficient asked for here.
B0.18
0.18 results from dividing the difference by the mean impedance rather than by the sum.
C0.27
0.27 is only the impedance difference; it must be divided by the sum of the two impedances.
D0.09 ✓ Correct answer
R = (Z2 - Z1) / (Z2 + Z1) = 0.27 / 3.03, which is about 0.09.
Reference: IAEA Diagnostic Radiology Physics (2014), Section 12.2.3 (Reflection and transmission)
Ask a friend
06A PET centre calibrates an 18F-FDG dose at 740 MBq at 10:00. The half-life of 18F is 110 min. The patient is injected at 13:40. What activity is injected?
Practice question Unit: Nuclear Medicine
A370 MBq
This is the activity after only one half-life, 110 min. The dose has waited twice that long before injection.
B185 MBq ✓ Correct answer
From 10:00 to 13:40 is 220 min, two half-lives of 110 min, so 740 MBq falls to 370 and then to 185 MBq.
C555 MBq
A 25% loss would ignore the exponential law. After 220 min the activity has fallen to one quarter, far below this value.
D740 MBq
This ignores decay altogether. 18F decays steadily during the 220 min wait, so the injected activity must be lower than the calibrated value.
Reference: IAEA Nuclear Medicine Physics (2014), Section 1.4.1 (Decay of radioactive parent)
Ask a friend
07In a DSA study the mask image and the fill image each show a noise level of 2.0% in the same region. Subtraction combines quantum noise in quadrature. What is the approximate noise in the subtracted image?
Practice question Unit: Angiography
A1.4% (lower than either image)
Subtraction does not lower noise; the quantum noise of two independent images adds, so the result is higher than either image.
B2.0% (unchanged by subtraction)
Noise would stay at 2.0% only if one image contributed none; both images add noise, so the level rises above that of a single image.
C2.8% (a factor of 1.4 higher) ✓ Correct answer
Noise adds in quadrature: the square root of 2.0 squared plus 2.0 squared is about 2.8%, a factor of 1.4 higher, so DSA needs more exposure.
D4.0% (the simple sum of both images)
A simple sum of 4.0% would apply to direct addition of noise levels; independent quantum noise combines in quadrature and gives a smaller value.
Reference: IAEA Diagnostic Radiology Physics (2014), Section 8.4.2 (Digital subtraction angiography) and Section 4.5.4.1 (Image subtraction)
Ask a friend
08Contrast medium is injected into a right antecubital vein for a chest CT. Which vessel carries the opacified blood directly into the left atrium?
Practice question Unit: General Anatomy
APulmonary veins ✓ Correct answer
After the lungs, blood returns through four pulmonary veins, two on each side, which empty directly into the left atrium.
BSuperior vena cava
The superior vena cava carries the injected contrast to the right atrium, not to the left atrium.
CCoronary sinus
The coronary sinus drains heart muscle into the right atrium and is not on the path to the left atrium.
DPulmonary trunk
The pulmonary trunk fills earlier but leads to the lungs, so it does not empty into the left atrium.
Reference: OpenStax Anatomy and Physiology 2e, Section 20.5 (Circulatory Pathways)
Ask a friend
09A CT of the pelvis is clearly indicated for a pregnant patient. Which approach follows the guidance?
Practice question Unit: Patient Safety
AUsing a low dose protocol and minimising the scanned area ✓ Correct answer
Low dose CT protocols and the smallest necessary scanning area are advised when CT is indicated during pregnancy.
BUsing the routine protocol to keep image quality high
Routine pelvic CT with and without contrast can deliver about 50 mSv to the uterus, so routine settings are not appropriate.
CAdding a contrast phase to reduce repeats
The guidance notes that routine pelvic CT with and without contrast injection can lead to about 50 mSv to the uterus, so an extra contrast phase does not lower dose.
DUsing the routine protocol with a lead apron over the abdomen only
The guidance asks for a low dose protocol and a minimal scanning area; keeping the routine protocol does not meet that, whatever is placed over the abdomen.
Reference: IAEA SSG-46 (2018), para. 3.161
Ask a friend
10A medical equipment company invites a radiographer to attend a conference as a delegate and offers to pay his flight, hotel and a daily allowance personally. A meal is also provided to all participants. Which response is consistent with the Code?
Practice question Unit: Professionalism and Ethics
AAccept the flight and hotel but refuse the daily allowance
Travel and accommodation subsidies paid personally are also not allowed; accepting part of the package does not solve it.
BAccept everything because the conference is educational
An educational purpose does not change the rule; personal compensation for travel, stay or time is not permitted.
CAccept the allowance only if hidden from the employer
Hiding the payment compounds the problem; the personal payment itself is what the Code prohibits.
DDecline the personal payments and accept the shared meal ✓ Correct answer
Personal subsidies for travel, accommodation or time are not allowed, but meals offered to all participants may be accepted.
Reference: SCFHS Code of Ethics for Healthcare Practitioners (2014), Chapter 10: Ethics of Financial Affairs in the Healthcare Field, (E) Gifts and Benefits, Corporate gifts
Ask a friend