حلّ الأسئلة في الاختبار أعلاه أولًا، ثم افتح كل سؤال هنا لترى الإجابة الصحيحة وسبب خطأ كل خيار.
01A procedure delivers equivalent doses of 10 mSv to the lung and 20 mSv to the thyroid, and negligible dose elsewhere. Using ICRP 103 tissue weighting factors (lung 0.12, thyroid 0.04), what is the effective dose?
سؤال تدريبي الوحدة: الحماية من الإشعاع
أ2.8 mSv
This swaps the weighting factors, using 0.04 for the lung and 0.12 for the thyroid, which gives 0.4 plus 2.4.
ب15 mSv
This is the simple mean of the two equivalent doses. Effective dose needs each dose multiplied by its tissue weighting factor.
ج30 mSv
This simply adds the two equivalent doses and ignores the tissue weighting factors, which are all below one.
د2.0 mSv ✓ الإجابة الصحيحة
E is the sum of wT × HT: 0.12 × 10 = 1.2 plus 0.04 × 20 = 0.8, which gives 2.0 mSv.
المرجع: IAEA Diagnostic Radiology Physics (2014), Section 22.3.4 (Effective dose, Table 22.1)
اسأل صديقًا
02A technician notes that the spectrum of a tungsten-anode tube at 60 kV contains no K characteristic lines. What is the reason?
سؤال تدريبي الوحدة: الأشعة السينية
أThe 2.5 mm Al filtration absorbs the K radiation completely
Typical filtration of 2.5 mm Al absorbs the L radiation completely, but it does not remove tungsten K radiation at higher voltages.
بElectron energy is under tungsten's 69.5 keV K-shell binding energy ✓ الإجابة الصحيحة
A K-shell vacancy needs an electron with more kinetic energy than 69.5 keV, which a 60 kV tube cannot supply.
جThe high atomic number of tungsten suppresses all characteristic emission
Tungsten does produce K lines at high enough voltage; its high atomic number actually favours the bremsstrahlung yield.
دThe tube current is too low to create enough K-shell vacancies
Tube current scales the number of photons but does not decide whether the K shell can be ionized; that depends on electron energy.
المرجع: IAEA Diagnostic Radiology Physics (2014), Section 5.2.2 (Characteristic radiation)
اسأل صديقًا
03A scanner has 16 detector rows of 1.25 mm, so the nominal beam width is 20 mm. In a helical scan the table moves 30 mm during each 360° rotation. What is the pitch?
سؤال تدريبي الوحدة: التصوير المقطعي المحوسب
أ1.5 ✓ الإجابة الصحيحة
Pitch is table translation per 360° rotation divided by nominal beam width: 30 mm divided by 20 mm gives 1.5.
ب0.67
0.67 inverts the ratio: it is 20 divided by 30 rather than table travel divided by beam width.
ج1.0
A pitch of 1.0 would need the table to move exactly 20 mm per rotation, equal to the nominal beam width.
د2.0
2.0 would need 40 mm of table travel per rotation for this 20 mm beam; 30 mm gives a smaller ratio.
المرجع: IAEA Diagnostic Radiology Physics (2014), Section 11.5.3 (Helical CT scan)
اسأل صديقًا
04At 1.5 T the ratio of parallel to antiparallel proton spins is about 1.000010. Roughly how many excess parallel spins are there in a group of 2 million spins?
سؤال تدريبي الوحدة: التصوير بالرنين المغناطيسي
أ1
An excess of one spin would need a ratio of only about 1.0000010, ten times closer to unity than the stated value.
ب100
An excess of 100 spins would need a ratio near 1.0001, ten times larger than the stated value at 1.5 T.
ج1000
An excess of 1000 spins would need a ratio near 1.001, far above the tiny polarization that actually exists at 1.5 T.
د10 ✓ الإجابة الصحيحة
Each half holds about one million spins, and a ratio of 1.00001 means about ten more spins point along the field.
المرجع: IAEA Diagnostic Radiology Physics (2014), Section 14.2.2 (External magnetic field and magnetization)
اسأل صديقًا
05An ultrasound pulse meets a boundary at normal incidence. Fat has an acoustic impedance of 1.38 MRayl and liver 1.65 MRayl. What is the magnitude of the pressure reflection coefficient?
سؤال تدريبي الوحدة: الموجات فوق الصوتية
أ0.008
0.008 is the intensity reflected (R squared), not the pressure reflection coefficient asked for here.
ب0.18
0.18 results from dividing the difference by the mean impedance rather than by the sum.
ج0.27
0.27 is only the impedance difference; it must be divided by the sum of the two impedances.
د0.09 ✓ الإجابة الصحيحة
R = (Z2 - Z1) / (Z2 + Z1) = 0.27 / 3.03, which is about 0.09.
المرجع: IAEA Diagnostic Radiology Physics (2014), Section 12.2.3 (Reflection and transmission)
اسأل صديقًا
06A PET centre calibrates an 18F-FDG dose at 740 MBq at 10:00. The half-life of 18F is 110 min. The patient is injected at 13:40. What activity is injected?
سؤال تدريبي الوحدة: الطب النووي
أ370 MBq
This is the activity after only one half-life, 110 min. The dose has waited twice that long before injection.
ب185 MBq ✓ الإجابة الصحيحة
From 10:00 to 13:40 is 220 min, two half-lives of 110 min, so 740 MBq falls to 370 and then to 185 MBq.
ج555 MBq
A 25% loss would ignore the exponential law. After 220 min the activity has fallen to one quarter, far below this value.
د740 MBq
This ignores decay altogether. 18F decays steadily during the 220 min wait, so the injected activity must be lower than the calibrated value.
المرجع: IAEA Nuclear Medicine Physics (2014), Section 1.4.1 (Decay of radioactive parent)
اسأل صديقًا
07In a DSA study the mask image and the fill image each show a noise level of 2.0% in the same region. Subtraction combines quantum noise in quadrature. What is the approximate noise in the subtracted image?
سؤال تدريبي الوحدة: التصوير الوعائي
أ1.4% (lower than either image)
Subtraction does not lower noise; the quantum noise of two independent images adds, so the result is higher than either image.
ب2.0% (unchanged by subtraction)
Noise would stay at 2.0% only if one image contributed none; both images add noise, so the level rises above that of a single image.
ج2.8% (a factor of 1.4 higher) ✓ الإجابة الصحيحة
Noise adds in quadrature: the square root of 2.0 squared plus 2.0 squared is about 2.8%, a factor of 1.4 higher, so DSA needs more exposure.
د4.0% (the simple sum of both images)
A simple sum of 4.0% would apply to direct addition of noise levels; independent quantum noise combines in quadrature and gives a smaller value.
المرجع: IAEA Diagnostic Radiology Physics (2014), Section 8.4.2 (Digital subtraction angiography) and Section 4.5.4.1 (Image subtraction)
اسأل صديقًا
08Contrast medium is injected into a right antecubital vein for a chest CT. Which vessel carries the opacified blood directly into the left atrium?
سؤال تدريبي الوحدة: التشريح العام
أPulmonary veins ✓ الإجابة الصحيحة
After the lungs, blood returns through four pulmonary veins, two on each side, which empty directly into the left atrium.
بSuperior vena cava
The superior vena cava carries the injected contrast to the right atrium, not to the left atrium.
جCoronary sinus
The coronary sinus drains heart muscle into the right atrium and is not on the path to the left atrium.
دPulmonary trunk
The pulmonary trunk fills earlier but leads to the lungs, so it does not empty into the left atrium.
المرجع: OpenStax Anatomy and Physiology 2e, Section 20.5 (Circulatory Pathways)
اسأل صديقًا
09A CT of the pelvis is clearly indicated for a pregnant patient. Which approach follows the guidance?
سؤال تدريبي الوحدة: سلامة المريض
أUsing a low dose protocol and minimising the scanned area ✓ الإجابة الصحيحة
Low dose CT protocols and the smallest necessary scanning area are advised when CT is indicated during pregnancy.
بUsing the routine protocol to keep image quality high
Routine pelvic CT with and without contrast can deliver about 50 mSv to the uterus, so routine settings are not appropriate.
جAdding a contrast phase to reduce repeats
The guidance notes that routine pelvic CT with and without contrast injection can lead to about 50 mSv to the uterus, so an extra contrast phase does not lower dose.
دUsing the routine protocol with a lead apron over the abdomen only
The guidance asks for a low dose protocol and a minimal scanning area; keeping the routine protocol does not meet that, whatever is placed over the abdomen.
المرجع: IAEA SSG-46 (2018), para. 3.161
اسأل صديقًا
10A medical equipment company invites a radiographer to attend a conference as a delegate and offers to pay his flight, hotel and a daily allowance personally. A meal is also provided to all participants. Which response is consistent with the Code?
سؤال تدريبي الوحدة: المهنية والأخلاقيات
أAccept the flight and hotel but refuse the daily allowance
Travel and accommodation subsidies paid personally are also not allowed; accepting part of the package does not solve it.
بAccept everything because the conference is educational
An educational purpose does not change the rule; personal compensation for travel, stay or time is not permitted.
جAccept the allowance only if hidden from the employer
Hiding the payment compounds the problem; the personal payment itself is what the Code prohibits.
دDecline the personal payments and accept the shared meal ✓ الإجابة الصحيحة
Personal subsidies for travel, accommodation or time are not allowed, but meals offered to all participants may be accepted.
المرجع: SCFHS Code of Ethics for Healthcare Practitioners (2014), Chapter 10: Ethics of Financial Affairs in the Healthcare Field, (E) Gifts and Benefits, Corporate gifts
اسأل صديقًا