01Next to a point-like source, a survey meter reads 120 µSv/h at 0.5 m. A technologist stands 2 m away. Ignoring scatter and attenuation by air, what dose rate is expected there?
سؤال تدريبي الوحدة: الفيزياء والسلامة الإشعاعية
أ7.5 µSv/h ✓ الإجابة الصحيحة
The distance is four times larger, so the dose rate falls by 4 squared, which is 16, giving 7.5 µSv/h.
ب60 µSv/h
This divides by 2 only, as if the 0.5 to 2 m change were a doubling.
ج15 µSv/h
This divides by 8, which does not correspond to any simple distance relationship for a point source.
د30 µSv/h
This divides by 4, treating dose rate as inversely proportional to distance rather than to its square.
المرجع: IAEA Nuclear Medicine Physics Handbook (2014), Chapter 10, Section 10.5.2, Eq. (10.4), p. 307
اسأل صديقًا
02A generator carries 20 GBq of Mo-99 on its calibration date. Using a Mo-99 half-life of 66 h, about how much Mo-99 remains 5 days later?
سؤال تدريبي الوحدة: الأدوية الإشعاعية
أ15.6 GBq
That is the activity left after only about 1 day, when roughly 78% remains.
ب2.5 GBq
That is three half-lives (198 h), far longer than the 120 h that actually passed.
ج5.7 GBq ✓ الإجابة الصحيحة
120 h is about 1.8 half-lives, leaving about 28% of the activity, which is 20 x 0.283 = 5.7 GBq.
د10.0 GBq
That is only one half-life, which would be reached after about 2.75 days, not 5 days.
المرجع: Technetium Tc 99m Generator prescribing information (FDA label), Table 3 (Mo-99 decay chart)
اسأل صديقًا
03In certain areas of a gamma camera crystal, the fraction of scintillation light collected is about 2% lower than average. The window is 20% wide and centred on 140 keV. What is the main consequence?
سؤال تدريبي الوحدة: الأجهزة
أSensitivity falls by about 2% there until an energy correction is applied ✓ الإجابة الصحيحة
The shifted photopeak puts slightly fewer events inside the window, so sensitivity is locally about 2% lower and an energy correction is needed.
بCounts are unchanged because a 2% shift is smaller than the window width
A small shift does move part of the photopeak out of the window, so a few counts are lost.
جAll photons in those areas are rejected, leaving a blank area
Most of the shifted photopeak still falls inside a 20% window, so only a small fraction is lost.
دCounts increase there because the shifted peak moves toward the window centre
The average peak is already centred, so shifting it either way moves it away from the centre and reduces counts.
المرجع: IAEA Nuclear Medicine Physics Handbook (2014), Chapter 11, Section 11.2.2.6, Fig. 11.18
اسأل صديقًا
04After a quarterly calibration, a uniform water-filled cylinder of 6,200 mL (6,200 g) containing 120 MBq of F-18 (decay corrected to scan time) is scanned, with its weight and activity entered as patient data. The mean concentration measured is 21.9 kBq/mL. What is the correct conclusion?
سؤال تدريبي الوحدة: مراقبة الجودة
أSUV is 0.88, outside 1.0 ± 0.1, so the calibration factor is set too high
That value inverts the ratio; the measured value is higher than expected, so the SUV is above 1.
بSUV is 1.00, because a phantom's mass in grams always equals its volume in millilitres
Equal mass and volume only gives an expected SUV of 1; the measured concentration still has to be checked.
جSUV is 1.13, acceptable because it differs from 1.0 by less than 15 percent
The accepted window is 1.0 ± 0.1, so 1.13 fails even though a looser 15 percent might pass it.
دSUV is 1.13, outside 1.0 ± 0.1, so recheck the entries and recalibrate ✓ الإجابة الصحيحة
Expected concentration is 120,000 kBq divided by 6,200 mL, about 19.4 kBq/mL, so SUV is 21.9 divided by 19.4, about 1.13.
المرجع: COMP/CPQR technical QC guidelines for PET/CT in radiation treatment planning, J Appl Clin Med Phys (2022), Table 4 (PT-Q1); IAEA Human Health Series No. 1, Quality Assurance for PET and PET/CT Systems (2009), Section 6.1.6.7
اسأل صديقًا
05An 80 kg patient is to receive the standard adenosine infusion of 140 mcg/kg/min for the full 6 minutes, with the tracer injected at the 3-minute mark. What total adenosine dose is infused over the whole 6 minutes?
سؤال تدريبي الوحدة: الإجراءات السريرية
أ84.0 mg
This overstates the dose and corresponds to a heavier patient or a longer infusion than described.
ب33.6 mg
This is the amount given in only the first 3 minutes, before the tracer is injected, not the full infusion.
ج44.8 mg
This would be the total for a shortened 4-minute infusion, but the stem specifies the standard 6-minute run.
د67.2 mg ✓ الإجابة الصحيحة
140 mcg/kg/min times 80 kg gives 11.2 mg per minute, and over 6 minutes the total is 67.2 mg.
المرجع: ASNC Imaging Guidelines for SPECT Nuclear Cardiology Procedures (2016), Adenosine stress, dose and procedure
اسأل صديقًا
06A vial of strontium-89 chloride has a concentration of 37 MBq/mL on its calibration date. The ordered activity is 148 MBq and it will be given 14 days after calibration, when 82.5% of the activity remains (physical half-life 50.5 days). What volume should be drawn up?
سؤال تدريبي الوحدة: الإجراءات السريرية
أ3.30 mL
This multiplies 4.00 mL by the 0.825 remaining fraction instead of dividing, so it under-delivers the activity.
ب4.85 mL ✓ الإجابة الصحيحة
Activity concentration on the day is 37 x 0.825 = 30.5 MBq/mL, so 148 / 30.5 is about 4.85 mL.
ج8.00 mL
This assumes a full half-life has passed and doubles the volume, but only 14 of 50.5 days elapsed.
د4.00 mL
This ignores decay and uses the calibration concentration, which would under-dose the patient by about 17 percent.
المرجع: Strontium-89 chloride injection USP, US prescribing information, Description (Table 1, decay of strontium-89) and Dosage and Administration (148 MBq)
اسأل صديقًا
07An outpatient signed consent for a diagnostic bone scan. Afterwards the physician considers a therapeutic radionuclide dose for the same patient, which is not an emergency. How should consent be handled?
سؤال تدريبي الوحدة: الإدارة والأخلاقيات
أTherapy may start now and consent can be recorded afterwards
A practitioner may exceed the consent's limits only in life-saving situations, and consent is obtained before the act, not after.
بA new consent for the therapy is needed first ✓ الإجابة الصحيحة
Therapy goes beyond the authorized scan, and outside life-saving situations the practitioner must not exceed consent given, so a new consent is needed.
جA relative's verbal agreement can replace the patient's own
A capable patient decides for himself; a relative cannot stand in for him.
دThe scan consent covers any nuclear procedure during that visit
Consent applies to the specified procedure and does not extend to a different one.
المرجع: Saudi Guidelines for Informed Consent, First Edition (2019), Conditions of Informed Consent; Conditions of Medical Practitioners
اسأل صديقًا
08A PET study is to be used for quantifying activity along a ring-shaped structure, including poorly converging attenuated central regions. Which reconstruction strategy suits quantification best?
سؤال تدريبي الوحدة: إنتاج الصور ومعالجتها
أRun many iterations and apply no smoothing, so that the noise is retained
High iteration numbers without smoothing give strong noise propagation, which harms quantification.
بUse FBP with the ramp filter alone, since it needs no iterations
A ramp filter alone amplifies noise, and it is not the iterative approach being compared here.
جUse one iteration only, with the largest number of subsets available
One iteration leaves most regions far from convergence, so recovery would vary with position.
دRun many iterations, then add a little post-smoothing ✓ الإجابة الصحيحة
Many iterations converge everywhere, and post-smoothing suppresses noise while giving fairly position-independent resolution.
المرجع: IAEA Nuclear Medicine Physics Handbook (2014), Chapter 13, Sections 13.3.5.1 and 13.3.5.2 (Position-dependent convergence; post-smoothed maximum-likelihood)
اسأل صديقًا
09On a long whole-body study, brain uptake looks symmetric on the uncorrected PET but asymmetric on the corrected PET. The CT was acquired head first and the PET feet first, with the head imaged last. What best explains this?
سؤال تدريبي الوحدة: تفسير الصور والآرتيفاكت
أHead movement as neck muscles relaxed misaligned the CT map and biased the corrected PET ✓ الإجابة الصحيحة
Misregistration over-corrects one side and under-corrects the other; reviewing both image sets and using head support helps.
بTruncation of the head because it lay outside the CT field of view at the couch end
The head is central in the field of view, and truncation would not produce a side-to-side difference.
جContrast pooling in the cerebral veins that raised the CT numbers in one hemisphere of the brain
Contrast pooling would give focal hot spots, not a hemispheric asymmetry.
دA true asymmetric tumour that is visible only after attenuation correction is applied
A real lesion would appear on the uncorrected PET as well, which looks symmetrical.
المرجع: IAEA Human Health Reports No. 7 (HHS27) PET/CT atlas of quality control and image artefacts (2013), Section 3.7.1 (head motion)
اسأل صديقًا
10A syringe holds 400 MBq in the dose calibrator before an intravenous therapy injection. After the injection and saline flush, the empty syringe and tubing read 30 MBq. What activity should be recorded as administered to the patient?
سؤال تدريبي الوحدة: رعاية المريض
أ400 MBq, the pre-injection reading before the injection
The pre-injection value ignores the residual retained in the syringe and tubing, so it overstates the dose delivered.
ب430 MBq, the pre-injection reading plus the residual
Adding the residual to the starting activity is the wrong direction and would overstate what the patient received.
ج30 MBq, the reading of the empty syringe and tubing
This is only the leftover in the syringe and tubing, which never reached the patient.
د370 MBq, the pre-injection reading minus the residual ✓ الإجابة الصحيحة
Subtracting the 30 MBq residual from the 400 MBq starting value gives the activity actually delivered, 370 MBq.
المرجع: IAEA Human Health Series No. 37, Nuclear Medicine Resources Manual (2020), Section 10.7.1 quoting SSG-46 para. 4.185, pp.149-150